Neware Battery Testing System

Neware BTS: Setup Guide & Common Paper Performance Data 2026

This article is split into two sections:   01 Neware BTS Operational Features   02 Common Paper Performance Data

01 Neware BTS Operational Features

1.1 Neware BTS 8.0 Right-Click Functions

Neware BTS 8.0 Right-Click Functions Settings
Neware BTS 8.0 Right-Click Functions Settings
Neware BTS 8.0 Right-Click Functions Settings 2
Neware BTS 8.0 Right-Click Functions Settings 2

You can find functions including Single Start, Single Stop, Set Parallel, Free Parallel, Set Chamber, Continue in the right-click menu function.

1.2 Continue

The system can resume testing interrupted by manually triggered “Stop” commands or “Protection” states caused by power loss, effectively preventing data loss.

Note:
1. Using “Stop” and “Continue” enables pausing and resuming channel testing.
2. Channels that have completed testing cannot be resumed.
3. After forced program termination or power loss, restarting the program will automatically resume testing.

Continue
Continue

1.3 Historical data combination & Batch historical data continuation

Note:

When using the “Historical data combination” feature, if the test data file being resumed was saved while the channel was in the “Stop” state, the channel status will remain “Stop” after importing the data file. You must manually right-click the channel and select “Continue” again for the channel to continue testing using the historical data.

Historical data combination
Historical data combination
Historical data combination
Historical data combination

1.4 Channel Move

Transfer the process parameters and test data from an unfinished test channel to another completed channel to continue testing. This prevents test interruptions caused by channel damage, thereby safeguarding the integrity of the testing process.

Note:
1. The channel being migrated must be in the “Stop” state.
2. Both the “channel being migrated” and the “new channel” must be selected simultaneously.

Channel move
Channel move

1.5 Set Parallel & Free Parallel

Connect two or more channels in parallel to increase the device’s current measurement range. The positive terminals of all paralleled channel sampling lines are connected together, and all negative terminals are connected together, serving as the positive and negative terminals for the paralleled channels.

1. Select the channels to be paralleled simultaneously; a yellow border around the channels indicates they are selected.

2. Refer to the technical specifications to verify whether the device hardware supports channel parallel operation and the maximum number of channels that can be paralleled.

3. Pulse and analog testing are not supported after parallel operation.

Set and free parallel
Set and free parallel

1.6 Reset Alarm(R)

If a buzzer is connected to the device, it will sound an alarm during channel protection. At this point, the alarm can be reset using the audible and visual alarm reset function.

Reset Alarm 1
Reset Alarm 1
Reset Alarm 2
Reset Alarm 2

1.7 Data Filter

Data can be filtered by time intervals or by the number of recorded data points, and supports the removal of voltage anomaly points.

Data Filter 1
Data Filter 1
Data Filter 2
Data Filter 2

1.8 Curves Comparison

  • Cycle contrast
  • Comparison of working steps
  • Overall comparison
Curves Comparison
Curves Comparison

You can directly copy the displayed image.

Curves Comparison
Curves Comparison

1.9 Two Methods for Setting the Amount of Active Substance

  • Method 1:

    Before starting the test, you can set the active substance quantity at the bottom of the process step settings interface in the Neware BTS software.

Active material
Active material
  • Method 2:

After completing the test, you can modify the active substance quantity in Neware BTSDA—Cycle statistics/calculation. Once confirmed, the software will recalculate and allow you to re-export the report. Or you can just right-click directly in the data area.

Cycle statistics calculation
Cycle statistics calculation
Cycle statistics calculation Active Material
Cycle statistics calculation Active Material

02 Common Paper Performance Data

2.1 C-rate Performance

C-rate is a relative indicator of a battery’s charge/discharge capability, defined as: The current intensity that can be discharged within one hour at the rated capacity. Example: For a 2200mAh battery, 1C = 2200mA, 2C = 4400mA (discharged in 30 minutes).

The importance of rate performance in evaluating battery material properties and overall battery performance is reflected in:

  1. Material Selection: Different battery materials exhibit varying impacts on rate performance. For instance, certain materials may perform well at low rates but experience rapid degradation at high rates.
  2. Battery Design: A battery’s rate performance influences its design, including electrode structure and electrolyte selection, to accommodate diverse application scenarios. Application Matching: Different applications demand varying rate performance capabilities. For instance, electric vehicles and power tools require high-rate performance to deliver instantaneous high-power outputs.
  3. Performance Optimization: Evaluating rate performance enables optimization of charging and discharging strategies, enhancing overall battery performance and lifespan.
  4. Safety Assessment: High-rate charging and discharging may increase risks of battery overheating and thermal runaway, making rate performance evaluation critical for battery safety.

Neware BTS 8.0 Software C-rate Mode

No need to calculate the current value manually. Simply input parameters such as the input C-rate value, nominal capacity/nominal specific capacity, and active material mass, and the current value will be automatically calculated.

C-rate Mode
C-rate Mode

Set—System settings—Step edit—C-rate step parameter—Nominal capacity

If you are conducting battery material research or testing coin cells and pouch cells, Nominal specific capacity is mostly what you need. If you are testing commercially sourced branded cells for quality inspection, Nominal capacity should be used instead.

Support for modifying units

Unit settings
Unit settings

C-rate Performance Data

C-rate Performance Data
C-rate Performance Data

2.2 Cycling Performance and Coulombic Efficiency

Cycling performance
Cycling performance
Coulomb efficiency
Coulomb efficiency

Cycling Performance and Coulombic Efficiency in Neware BTS

Cycling Performance and Coulombic Efficiency in Neware BTS
Cycling Performance and Coulombic Efficiency in Neware BTS

1. Charge/Discharge Specific Capacity Comparison Analysis: Comparing actual capacity with theoretical or nominal capacity to evaluate battery material performance.
2. Capacity Retention Rate Analysis: Assessing the trend of capacity retention rate over cycle life to evaluate long-term battery stability.

2.3 Ion diffusion coefficient D

The GITT test, as a standard method for characterizing battery electrode materials, integrates steady-state and transient testing techniques. Its principle involves applying a constant current to the electrode, recording potential changes before and after the pulse current, and monitoring the equilibrium potential shift after relaxation.
By analyzing the potential-time curve, information on the electrode process overpotential relaxation can be obtained, enabling the estimation and calculation of kinetic parameters.

Ion diffusion coefficient D
Ion diffusion coefficient D

4 formulas for calculating the GITT diffusion coefficient

How to set GITT test on Neware BTS for lithium-sulfur batteries? 2026 update

How to Calculate Ion Diffusion Coefficient Using GITT Function in Neware BTSDA?

GITT Function

Export ion diffusion coefficient D and lgD

(1) Export custom reports

lgD
lgD

(2) In the diffusion coefficient calculation interface, select “Export report” to export D and lgD.

Export D and lgD
Export D and lgD

2.4 Electrochemical Impedance Spectroscopy (EIS)

EIS measurement results for LPSCl, LPSCl|LiWS2|LPSCl, and LPSCl|Li2S|LPSCl.
EIS measurement results for LPSCl, LPSCl|LiWS2|LPSCl, and LPSCl|Li2S|LPSCl.

Chanho Kim, Gyutae Nam, Yoojin Ahn, Xueyu Hu & Meilin Liu,Nb1.60Ti0.32W0.08O5−δ as negative electrode active material for durable and fast-charging all-solid-state Li-ion batteries. Nature Communications, 2024. Original link:https://doi.org/10.1038/s41467-024-52767-8.

To compare the electrical conductivity of Li2S and LiWS2, the authors fabricated pellets and performed electrochemical impedance spectroscopy (EIS) analysis using LPSCl|LiWS2 or Li2S|LPSCl symmetric cell configurations.

Compared to pure LPSCl particles, those with embedded Li2S layers exhibited higher impedance values, while particles with intermediate LiWS2 layers showed a relatively smaller increase in total impedance. The experimental results indicate that the formation of the LiWS2 phase between the anode and solid electrolyte is more conducive to lithium-ion transport than the formation of the Li2S phase.

Note: The EIS software functionality has been developed, while the hardware functionality is currently undergoing debugging (this technology was first implemented on Neware device CT-8002S-5V100mA-EIS).

2.5 Cyclic Voltammetry CV Test (Neware BTS 8.0)

Parameter Settings:
Starting Voltage: 0 V relative to open circuit. Scan Rate: 1 mV/s.
Peak Voltage 1: 3.9 V relative to reference;
Peak Voltage 2: 2.6 V relative to reference.
Cycle Count: 5 times. Recording Interval: 3 mV.
Current Range: Select a range exceeding the maximum current during scanning. End Voltage: 0 V relative to open circuit (can be disabled by unchecking).

Neware Cyclic voltammetry curve
Neware Cyclic voltammetry curve

X-axis: Voltage (V); Y-axis: Current (mA). Cycle count can be modified and filtered.

Currently supported device models:
Neware CT-9000:5V6A/12A/15A
Neware CT-8002S-5V100mA-CV

Cyclic voltammetry (CV) is an electrochemical technique used to study electrode processes and evaluate electrochemical system properties. This method generates a voltammogram by applying a linearly varying potential to the working electrode at a fixed scan rate while measuring the resulting current. The resulting cyclic voltammogram provides information about electrode reaction kinetics and mechanisms.

Key Features of CV Testing:

  1. Potential Scanning: Gradually increasing or decreasing the applied potential to the working electrode at a fixed rate within a preset potential range.
  2. Current Measurement: Measures and records the current response at the working electrode. Changes in current reflect redox reactions occurring at the electrode surface.
  3. Cyclic Testing: Potential scans are typically cycled multiple times between forward and reverse directions to observe reversible and irreversible electrochemical reactions.
  4. Voltammetric Plot: The current-potential curve, known as a voltammetric plot, displays key parameters of electrochemical reactions such as onset potential, peak potential, and peak current.

2.6 Capacity Retention Rate

Capacity retention rate = (Current capacity / Initial capacity) × 100%

Capacity Retention Rate
Capacity Retention Rate

 

Feel free to contact Neware for our latest advanced battery testing solutions tailored to your needs.

From battery cyclers and chamber to Neware all in one
From battery cyclers and chamber to Neware all in one